rheem performance plus upper element light not on
Reviews for Rheem Performance Plus 40 Gal Medium 9-Year 5500/5500-Watt The temperature of the water in the water heater can be regulated by setting the temperature dial of the adjustable surface mounted thermostat(s) located behind the jacket access panel(s). Electric tall water heater provides an ample supply of hot water for households with 3 to 5 people. Nice appliance. 0000008643 00000 n Polypropylene Side-Mount Runoff Tube, 3 1/4 in. Turn off power and water to the unit, and turn off the well pump, if applicable. And confirmed by the Whirlpool wiring diagram. Performance Plus 40 Gal Medium 9-Year 5500/5500-Watt Elements Electric Tank Water Heater with LED Indicator . 2000-2022 Home Depot. . oldturkey03. . Feb 5, 2022 by An electronic LED system indicates element and thermostat operation. To check the lower one, I set the upper to the lowest setting (so it would shut off quickly) and then had power to the lower one. The purpose of these lights are to indicate the power and element status of the water heater. Rheem Performance Vs Performance Plus - Stories of a House Remove the part from its packaging. Area free of flammable vapors. Exclusive to the Home Depot! The upper element heats the upper portion of the water column. This unit comes with two 4500 watt elements and an automatic thermostat which keeps the water at the desired temperature, providing faster hot water delivery. Rheem XE40M09EL55U1 download instruction manual pdf E FIG. Performance & security by Cloudflare. Evacuate your home, and call a repair technician or the gas company. art description (as noted below) and P number of parts desired. What make and model is our water heater? Remove and clean the heating elements. Then, use the wrench to tighten it until there are no leaks. Answered in 10 minutes by: HVAC Technician: Gaztech1 Hello! If you replaced an electric element, remove the cover to it, and check/tighten the element if necessary. Watt Densities: Lower watt densities mean the element stays cooler and will last longer. I use this webpage to test my water heater: http://waterheatertimer.org/How-to-test- New thermostats, new bottom element. The fittings are electro zinc plated and polypropylene lined. The Rheem Performance Line. Rheems light-duty commercial electric water. 8 Operating Instructions Safety Controls . Replacement Parts. Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. ){xZ$/d22% C This takes pressure off the water tank. Make sure electric supply to water heater and disconnect switch, if used, are in the ON position. Questions of a Do It Yourself nature should be submitted to our "DoItYourself.com Community Forums". We formed this web site so consumers could have an educational place to go for good, solid information. NPT x 63 in. Heats water quick and with luck it will last half as long as older one. through 120 Gal. 0000020302 00000 n You checked the power? UPPER THERMOSTAT & HIGH TEMP. Easily convert standard models from simultaneous to non-simultaneous and single phase to three phase. Replace fuse or reset circuit breaker. Thank you for the diagram - I will do some more testing with my meter. Home Rheem Water Heater Troubleshooting - Common Problems and Solutions. 1) Power on and bottom element presently heating water. q/ vQZUO ]eGIl$=yaMWFlj Installation Checklist A. Answer Summary Gaztech1 here,I am ready to assist you with your issue. Cold water inlet temperature may be colder during the winter months. Some models may require you to push a reset button on the thermostat prior to changing the temperature. Please call us at: 1-800-HOME-DEPOT (1-800-466-3337), Please enter in your email address in the following format: you@domain.com. Its probably time for a new water heater. We had 9 people at our home over Christmas and never had a hot water issue. A tripped circuit breaker will shut down an electric heater and gas models that use electricity. Performance Plus Series: High Efficiency Electric, PERFORMANCE PLUS High Efficiency electric water heaters are engineered for longer life and feature an electronic LED system, 125 Edgeware Rd Unit 1, Brampton, Ontario, Canada, L6Y OP5. WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of water heaters thermostat. If your home is in a state that requires Demand Response water heaters, please select an approved Demand Response model available on homedepot.com. Many modern homes come with dual-element water heaters. If the water heater is new, or if youve just moved into a new home and arent familiar with the water heaters capability, its likely that the unit is undersized. Use a screwdriver to disconnect the wires to the bad element or thermostat. DANGER: There is a hot water scald potential if the thermostat is set too high. Are the factory installed in/out pipes dielectric? Old water heater had internal leak not noticed until it was leaking all over. racknrollapa, Feb 16, 2020 by 0000001863 00000 n . Weve included several safety steps in this Rheem water heater troubleshooting guide to prevent burn and shock. When it reaches a specified temperature, Rheem notes that it shuts off, and the lower heating element takes over, heating the rest of the water. Pay particular attention to the Safety Instructions. . After 9 days have hot water again. On a 240 volt water heater, there will always be 120 volts to both elements. The Rheem Performance Plus 50 Gal. 208 Volt 8 kW Multi Phase Field Convertible Electric Tank Water Heater, Electronic LED system indicates element and thermostat operation, Make sure it fits: measure your space to ensure dimensions fit, WA Residents see disclaimer below before purchasing. Rheem Water Heater Troubleshooting - Common Problems and Solutions When replacing a heating element, shut off water leading to the water heater. Wiring checks out okay. Must check every element which are parts of main after installed. If you do not understand, these instructions or any terms within it, seek, water heater should be directed to the seller, from whom it was purchased. Replaced a less than three year old water heater of the exact same model due to the bottom rusting out. This label is also located on the water heater near the thermostat access panel. 0000001833 00000 n The colder inlet water takes longer to heat. @kasten39828. Jul 1, 2019 by 208 Volt 6 kW Multi Phase Field Convertible Electric Tank Water Heater, Commercial Light Duty 30 Gal. iFixit Answers is free since people answering questions on here are volunteers. View our Privacy Policy here. Local codes shall govern the installation of relief valves. 0000191623 00000 n Rheem Performance Plus 50 gal. Medium 9 Year 4500/4500-Watt Elements Rheem Performance Plus 50 Gal. Tall 9 Year 4500/4500-Watt Elements Turn it all the way to Off, and then turn it to the On position. WA Indoors and protected from freezing temperatures. Air purged from water heater and piping. Rheem Performance Plus 63 Gallon (285L) 10 Year 4.5kW Tank Electric Hello, Indicates heating element and thermostat operation. 0000008181 00000 n Just installed it about 3 weeks ago, so far so good! can cause the water heater to be electrically isolated. Be careful with this site. Not enough or no hot waterWater usage may have exceeded the capacity of the water heater. They are available in 3kW through 12kW and in 208-Volt, 240-Volt, 277-Volt and 480-Volt. 0000295269 00000 n If I had done the install myself I might have thought the lower element was defective. Note: If youd prefer not to have a small amount of water leak from the tank while replacing the element, drain the tank first by attaching a garden hose to the threaded spigot near the bottom of the tank, running the hose to a floor drain or to the outside of your home and turning on the spigot. The four added wires are shown below attached to the harness connector. . . When it reaches a specified temperature, Rheem notes that it shuts off, and the lower heating element takes over, heating. otate the crossbar up and down until it breaks away R from the remainder of the cavity insert. Plastic Water Heater Pans with PVC Drain Connection (Case of 20), The Rheem Gladiator 50 Gal. A fuse is blown or a circuit breaker tripped. Worked great! %PDF-1.5 % Finally an explanation on why the top element alone burning out can result in zero hot water even though there's a healthy lower element there. Safety Information Safety Precautions. Copyright 2020 - 2022 | All rights reserved. Vincent Garofalo, Blaise Werner If the unit still doesnt make enough hot water, it is either undersized for your needs, partially filled with mineral sediment or has a plugged gas valve. This unit comes with two 4500-Watt elements and an automatic thermostat which keeps the water at the desired temperature. Have a question about Rheem Performance Plus 50 Gal. Medium 9 Year 5500 0000017839 00000 n 0000022811 00000 n 1) Power on and heating cycle complete. . No it can not. Checked power, reset the. This unit comes with two 4500-Watt elements and an automatic thermostat which keeps the water at the desired temperature. Requires 240 volt electricity (a 30 amp breaker, with 10 gauge wire from the panel 10 year tank and parts, 1 year labour limited warranty. This model comes with 2 4500-Watt stainless steel heating elements. 2: pdf: 885.43KB: View Full View Download Featured Content 1 Rheem s performance; 2 Call 1 800 homedepot; . The second one has incomplete threads on the cold side and needed to be returned. The Lower light did not light right away. Do Not Sell or Share My Personal Information. 0000022393 00000 n I should note that my water heater has indicator lights on the outside so you can see when a given element is running, and we had noted that the upper element NEVER seemed to run, and even when I turned the upper all the way to 150 and the bottom all the way down, it would not send power to the upper element. If the thermostat is set above 120F, turn it down to that temperature or lower. In HOT WATER again! . If the carbon monoxide detector goes off, evacuate the area. Spring came and again things were fine so I forgot about it. . No valve of any type should be installed between the relief valve and the tank. You're using hot water faster than it can make it. 21 yrs on old water heater not too bad. This unit comes with two 5500-Watt elements and an automatic thermostat which keeps the water at the desired temperature. About 2 years ago, my then 12 year old water heater failed and I replaced it with a new Rheem Performance Plus 50 gallon model purchased from Home Depot. Status Light Wiring Diagram (if installed) G * L2 RED BLACK L1 JUNCTION BOX When factory installed with the status light feature, the wiring will feature four additional wires to connect to the top cavity cover light system. That night the water was nice and hot. Turn off power to the unit, if applicable, and check all pipe connections for water. Just installed a brand new Rheem Performance 40 Gal. 0000020868 00000 n All rights reserved. For 2055 gallon models with single and double elements. Plumbing, Piping, Water Heating, Wells, Air & Water Filtration and Conditioning, How to Prevent Ongoing Clogs in a Utility Sink, Have Power but Water heater won't heat/kick on. 0000082488 00000 n Rheem Performance Plus 63 Gallon (285L) 9 Year 4.5kW Tank Electric All Rights Reserved. An electronic LED system indicates element and thermostat operation. Jun 27, 2017 by oldturkey03. Rheem Water Heater Troubleshooting | Appliance Helpers . C 1 FIG. FHR: 52 - 63 gallons, based on gallon capacity. Rick is online now Continue Questions the Experts can answer 1. This might require a flat screwdriver placed in the slot on the adjuster. CAUTION: Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a long period of time (generally two weeks or more). If the valve leaks because it is too loose, tighten it another quarter to half a turn. Electric medium water heater provides an ample supply of hot water for households with 2 to 4 people. 40 gal Medium 4.5kW 2-Element Residential Electric Water Heater (PROE40M2650265) at Ferguson. So I just put a new element in causetop read 240 bottom 110 so figured lower element was bad baught new one right on looked on water heater and now lower one reads nothing have checkedbreaker there fine any help! 2. A 240-Volt electrical connection is required for installation. Factory installed temperature and pressure relief valve and 3/4 in. They sometimes burn out. The Rheem Performance Plus 50 Gal. Leaking or open hot water faucets. Installing the water heater. 0000007980 00000 n . California building code requires all new or retrofit water heaters be installed using an approved method to secure the water tank to the wall. 0000008413 00000 n Installing the water heater. New heater will shutdown the water and electric until service is done! 0000019645 00000 n D 2 LOWER HEATING ELEMENT LOWER HEATING ELEMENT LOWER HEATING ELEMENT FIG. 9 0 obj <> endobj xref 9 36 0000000016 00000 n Water Connections . Adjust it to a higher temperature, but no higher than 120F. Checked power, reset the breaker, has power on both the elements. Related Error Code Pages:Rheem Air Conditioner Error Codes, Rheem Furnace Error Codes, Rheem Water Heater Error Codes. Rumbling noise Water conditions in your home caused a build up of scale or mineral deposits on the heating elements. Isolated tank design reduces conductive heat loss, Dual 5500 or dual 4500 watt copper heating elements, FHR: 52 - 63 gallons, based on gallon capacity, Indicates heating element and thermostat operation, Premium grade anode rod provides long-lasting tank protection, High performance and lower operating cost, Compliant with many electric utility incentive programs, Electric junction box located above heating elements for easy installation, Over-temperature protector cuts off power in excess temperature situations, Temperature and pressure relief valve included. Installing the water heater. Action; Energy Guide. WARNING: If local codes require external application of insulation blanket kits the manufacturers instructions included with the kit must be carefully followed. This is normal for heat trap fittings when in operation and does not indicate a need for service. . This is known as a flip/flop system. Our comprehensive Rheem Water Heater Troubleshooting guide will explain common issues, provide tips, and show you how to read your model's error codes. Rheems light-duty commercial electric water heaters with Terminal Block are field convertible to meet any light duty hot water application need. YluTVV|piyd`X\_d 4rg@f%L!eg@QA#) $pIMfSTaZd`5aN&X~@;lR5JjOfBPLnz+}c) What is your household voltage 110V (North America) or 220/240 (Europe)? For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. Jun 27, 2017 by Local store prices may vary from those displayed. Electric supply may be off. Instructions For Placing a Parts Order Address parts orders to the distributor or store where the heater was purchased. Need Help? If everything is tight, the next step is to determine if the relief valve releases water. Apr 19, 2021 by If the circuit breaker in your electrical panel is in the Off position, turn it to the On position. I've also read this could be the result of a faulty expansion tank. Staple sales slip or cancelled check here. A premium grade anode rod provides long-lasting tank protection. Performance Mode: Applies only to unit when set point is between 1300F and 1400F. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. 1) Power on and heating cycle complete. All models shipped in simultaneous configuration. If the water continues to be warm but not hot or heats very slowly, then one of the heating elements or thermostats is bad. electric water heater provides an ample supply of hot water for households with 3 to 5 people. If additional, information is required, refer to the section on, 50 gal. The purpose of these lights are to indicate the power and element status of the water heater. Be careful not to overtighten it. In order to drain the water heater, turn off the cold water supply. These water heaters start at a UEF of 54 and max out at 81 for the most efficient models. Make sure you have no running water in your or outside of your house and go check the meter and see if its spinning and if it is you need to go into your crawl and find your leak. Click here to log in to MyRheem to browse our product training library. If it is midway between the two, it has been tripped. I just bought and had a plumber install yesterday a Rheem Performance . On a duel element residential water heater, both elements do not heat at the same time. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! Quickly loosen the element with the wrench first and then with your hand. John Bryant, Same here Top is fine and makes hot water, Aug 2, 2020 by The water leak from the top heating element wasn't tightened enough. Should you have any questions about your new water heater, or if it requires adjustment, repair, or routine maintenance, it is suggested that you first contact your installer, plumbing contractor or previously agreed upon service agency. Remove the access cover panels located on the side of the tank. Electric medium water heater provides an ample supply of hot water for households with 3 to 5 people. In order to replace the thermostat or heating element, remove the cavity insert crossbar by following the instructions below: Turn off the power to the water heater. I ended up just turning the lower thermostat to 150 and lived with it like that as we could get by that way. Rheem water heater troubleshooting allows you to find pressure relief valve to some common issues or indicates professional repair or replacement is needed. 0000021899 00000 n *HublQDM#^yR#,1^z(^WCC7o (i{{JqB,E{s.Z=*jd*Jv] fzyA]c{*[=Em `W7L V$' Turn off the circuit breaker to the water heater. If each element is on a separate thermostat the one connected to that element may be bad or the element itself may be. Water Supply Water heater completely filled with water. Copyright 1995-document.write(new Date().getFullYear()) MH Sub I, LLC dba Internet Brands. Water temperatures above 125F can cause severe burns or death from scalding. You checked the fuses to those lines? 1: pdf: 298.79KB: View Download. The Power to Control: integrated EcoNet Wi-Fi enables management of water temperature, tracking of energy usage and monitoring from your phone. Do the same with the wrench when replacing a heating element. O G 9k8B They sometimes burn out. Installed myself in less than an hour and works great. 0000001706 00000 n After some troubleshooting on the phone with a multi-meter, Rheem sent a replacement upper thermostat. All Rights Reserved, Rheem Water Heater Troubleshooting - Common Problems and Solutions, Rheem Water Heater Troubleshooting Summary, If the water from the hot tap goes cold, give a gas unit 15 minutes and an. Hi Rays and thank you for your question. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Never buy another water heater after the Rheem Marathon 50 Gal. installation and adjustment of the water heater; the features, operation, safety precautions, maintenance and troubleshooting of the water, It is imperative that all persons who are, expected to install, operate or adjust this, water heater read the instructions carefully, these operations. thanks. I just installed the Rheem performance plus water heater 39 gallons, the power light, and upper element light are on but Ask an Expert Home Improvement Questions HVAC Questions HVAC Rick, HVAC Supervisor 39,246 Satisfied Customers 50+ yrs. Problem Possible Causes What To Do Rumbling noise Water conditions in your home caused a build up of scale or mineral deposits on the heating elements. A check valve located in the cold water inlet line can cause what is referred to as a closed water system. Relief valve Pressure build up caused producing popping by thermal expansion noise or draining in a closed system. Melvin Cleveland, alienpilot65 . Also has WiFi that will notify me of any problems or need of service. The thermostat may be set set too low. An electronic LED system indicates element and thermostat operation. 0000001642 00000 n Contact the water supplier or plumbing contractor on how to correct this. Longer Life. Press and held the reset button for 10 seconds and the automatic shutoff cycles read more. @jrbryant so you have a water heater where the bottom element is not working? F ! Related Parts Pages:Rheem Air Conditioner Parts, Rheem Furnace Parts, Rheem Water Heater Parts. A 63 gallon electric water heater providing an ample supply of water to households with 5 - 6 people. DoItYourself.com, founded in 1995, is the leading independent home improvement and repair website. Remove and clean the heating elements. Use of this site is subject to certain Terms Of Use. All parts orders should include: ! The upper element heats the upper portion of the water column. 0000001331 00000 n Provisions made to protect area from water damage. To dissipate such gas and to reduce risk of injury, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. The upper and lower elements take turns heating the water, you will never have power to both at the same time. Turn off the pumps circuit, if you have a well and pump. What Would Cause an Electric Hot Water Tank to Use More Electricity Than Normal? electric water. How to Set the Upper and Lower Thermostats on Dual-Element Water All information is provided "AS IS." Peel back the insulation inside the tank to access the thermostat, according to CNET. 0000018041 00000 n Now on the third one, the relief valve is allowing water to accumulate at the top and where the electrical connections are located. xZ{tT>f#3Idfdd2A @H DI,~E[VVLm+>VKkORR)3v~3y> `AeXPlUWvE7Ux>}+ ~ +dVbt?}tWvmJ+{6 z+]G 4Oh|{=bVO`-rN n\RIV#d8ad##vu+[8g3xHQfdH{{gDr!I+`;T`me5pG%6mqWXE#SIYDV!r*'3Pv"h'$8r5df/m wl"}"^JvL< LgPWeHRt3}-1ShyRg^8;`vh'QK"49ST9~{xYlFRB/6Xlap,g>z+B6 ?`2\ N6+GC_x=nWaVd49V24EHDlmD$]WrWedy)hT&>MJ`Ceb+e%kDwg'hZRXuC}"G"M3 Installing the water heater. Had it for about a month now. 0000001748 00000 n What could be the most likely cause? 0000019604 00000 n Medium 9-Year 4500/4500-Watt Elements Electric Water Heater with LED Indicator provides ample amount of hot water for households with 3 to 5 people. Dual element heaters have two thermostats. This small collection of items will assist you in Rheem water heater troubleshooting and possibly making a repair. This uses less electricity, lowering your electricity bill. They can evaluate whether you can repair or replace your water heater. Website operating problems contact Webmaster. Performance Plus 50 Gal. The recalled water heaters are gray and have the "Performance Platinum" Rheem logo decal on the front above the thermostat control panel. If the unit has a pilot light (see your manual), check to see if it is lit. The Power to Protect: Features the LeakGuard Auto Shutoff Valve, which engages in the unlikely event a leak is detected, to protect your home from water damage. . Reviews for Rheem Performance Plus 50 Gal. Medium 9 Year 5500/5500-Watt As a Performance Platinum, the Gladiator has a 12-year limited tank and parts warranty plus a 3-year in home labor warranty. The Rheem Performance Plus 40 Gal. Cloudflare Ray ID: 7c0f1cfb2b9e0198 . 110 v to the lower red wired line but no voltage to the black wired line. Shop Medium Wood Bathroom Vanities without Tops, Single Sink Soft Close Doors Bathroom Vanities with Tops, Shop Party Digital display Portable Speakers, Shop Surface Mount Wall Plate Included Timers, 15 amp Plug Electrical Plugs & Connectors, 15 amp Siemens Electrical Panels & Protective Devices, Shop Dual Hose 12K BTU Portable Air Conditioners, Lasko Bladeless 1500-Watt 28 in. Remove and clean the heating elements. A few hours later, it was leaking again. Gas water heater: If your unit has a pilot light and it isnt lit, follow the instructions in your users manual to relight the pilot using the BBQ lighter. We welcome your comments and suggestions. Related Troubleshooting Pages:Rheem Air Conditioner Troubleshooting, Rheem Furnace Troubleshooting, Rheem Water Heater Troubleshooting. It was a bit taller than the old one but only by about 2 so no problem. Products shown as available are normally stocked but inventory levels cannot be guaranteed, For screen reader problems with this website, please call 1-800-430-3376 or text 38698 (standard carrier rates apply to texts). . Relief valve producing popping noise or drainingPressure build up caused by thermal expansion in a closed system. oldturkey03. Product Brochure. It is a good value. Stainless Steel Water Heater Supply Line, Upper Thermistor/ECO Replacement Kit for Rheem Performance Platinum Water Heaters, Indoor/Outdoor Whole House Electronic Descaler Conditioner Treatment System, EcoNet Home Comfort Wi-Fi Module for Performance Platinum Smart Electric Tank Water Heaters, 1/25 HP Hot Water Recirculating Pump with Under Sink Kit, 3/4 in. Sometimes the first shower of the morning would be piping hot, but other times it would be lukewarm. If water continues to drip or flow from the temperature/pressure relief valve, you can replace it with the following steps: If water isnt coming from a fitting or the T&P relief valve, the tank is leaking. This website is using a security service to protect itself from online attacks. Repair guides and support for gas and electric hot water tanks, boilers and household heat exchangers. http://www.water-heater-repair-guide.com Top has power, used a voltage meter, lights up, replaced bottom thermostat and element and voltage light don't light up, Nov 30, 2017 by Medium 9 Year 4500/4500-Watt Elements Electric Water Heater with LED Indicator. What make is your HW heater? Gas: Check if the gas valve has been turned off. Sufficient room to service heater. .
What Happened To Abby Steiner,
Frankie Brown Obituary,
Articles R
